Changes between Version 199 and Version 200 of SavinGroup/MergedBeams
- Timestamp:
- 10/09/09 18:28:24 (17 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
SavinGroup/MergedBeams
v199 v200 1 1 [[PageOutline]] 2 3 [../ Return to Savin Group Start Page] 4 2 5 = H,,2,, Formation in the Early Universe = 3 [[br]] 6 4 7 During the epoch of first star and protogalaxy formation the formation of these structures was mediated through H,,2,, which is an important coolant in primordial clouds. The dominant formation mechanism of H,,2,, during this epoch is the associative detachment (AD) reaction H^^-^^ + H → H2 + e^^-^^. Published values for this process differ by nearly an order of magnitude. This introduces uncertainties into cosmological models of structure formation and limits our understanding of protogalaxy formation during this epoch and of the characteristic masses and cooling times for the first stars. 5 8 … … 7 10 [[br]] 8 11 9 == ==12 == Experimental Setup == 10 13 11 [[br]]12 14 [[Image(https://docs.astro.columbia.edu/attachment/wiki/SavinGroup/MergedBeams/Apparuts%20Lens%20View%202.png?format=raw, 37%)]] 13 15 [[Image(https://docs.astro.columbia.edu/attachment/wiki/SavinGroup/MergedBeams/Apparatus%20top%20view%208.png?format=raw, 52%)]] 14 16 15 [[br]]16 == Experimental Setup ==17 17 The beamline is subdivided in several sections. Depending on status and time, we'll update the pages. 18 18 … … 24 24 * [https://docs.astro.columbia.edu/wiki/SavinGroup/MergedBeams/EndSection End Section] - Product detection section. 25 25 [[br]] 26 = The beam = 27 [[br]] 26 27 == The beam == 28 28 29 After some changes to the installed beam optics, we now get the source to emit 16 micro Amps! The beam shape is reasonable and, most importantly, pretty well centered. The beam is oval, about 6mm full diameter in the vertical and 3.5mm diameter in the horizontal direction. 29 30 … … 41 42 42 43 * Oxygen depletion: One floor above, there is the RARAF accelerator, filled with SF6. If there is a leak, since we're in the basement and SF6 is a lot heavier than air, it can flow into our transformer room through cable hatches and such. Even if the complete load of SF6 pours into our lab, it won't fill more than knee-height or so. However, if the doors to the generator room are closed it may fill up. We have an oxygen monitor installed at knee-height in the transformer room. It measures the oxygen partial pressure (and ''nothing'' else!). We have three alarm levels: Alarm 1: Oxygen level below 19.5%; Alarm 2: Oxygen level below 19%; Alarm 3: Oxygen level above 23% (monitor reliability check). According to the [http://www.osha.gov/SLTC/smallbusiness/sec12.html U.S. Department of Labor] oxygen levels below 17% are critical, so our alarm settings should be good. In case of an alarm, evacuate the lab immediately. Open all doors to the lab, including the hatch on the ceiling, and vent the lab for a good while. The alarm does ''not'' stop if the oxygen level is back to normal. Check what the RARAF monitors say about the oxygen levels ''if they don't get an alarm, too''. The RARAF oxygen monitor is installed on the wall between the RARAF accelerator control panel and the accelerator bay. If their readings are fine, have the RARAF people give you an SF6 sniffer. Have at least one additional (better two) person(s) stand at the door and watch you as you go in and check for SF6. Do not walk out of their sight. 43 44 45 == Vendors ==46 47 === Vacuum equipment ===48 * [http://www.pascaltechnologies.com Pascal Technologies]49 * [http://www.lesker.com Kurt J. Lesker]50 * [http://www.mdcvacuum.com/ MDC Vacuum]51 * [http://www.kimballphysics.com/ Kimball Physics] (also sell [http://www.kimballphysics.com/ion_guns/igun_prod.htm ion sources])52 * [http://www.huntvac.com/ Huntington Vacuum Components]53 * [http://www.varianinc.com/ Varian]54 * [http://www.cathode.com/ HeatWaveLabs] (In-vacuum components, i.e. insulators, clamps etc.)55 * [http://www.dowcorning.com/applications/search/default.aspx?R=988EN DowCorning: Molykote P-37 thread spray]56 * please add more57 58 === Power Supplies ===59 * [http://www.agilent.com Agilent Technologies]60 * [http://www.comdel.com/ COMDEL]61 * [http://www.emcohighvoltage.com EMCO High Voltage Corporation]62 * [http://gammahighvoltage.stores.yahoo.net/ Gamma High Voltage Research, Inc.]63 * [http://www.glassmanhv.com Glassman High Voltage Incorporated]64 * [http://www.heinzinger.com Heinzinger]65 * [http://www.hitekpower.com/ HiTek Power]66 * [http://www.instek.com/ Instek America Corp.]67 * [http://www.iseg-hv.de/start.php/lang.en/start ISEG]68 * [http://www.kepcopower.com/ KEPCO]69 * [http://www.magnavolt.com/ Magnavolt]70 * [http://www.powersupplydepot.com/ Marlin P. Jones & Assoc., Inc.]71 * [http://www.matsusada.com/ Matsusada Precision Inc.]72 * [http://www.ortec-online.com ORTEC]73 * [http://www.spellmanhv.com Spellman High Voltage Electronics Corporation]74 * [http://www.thinksrs.com/ Stanford Research Systems]75 * [http://www.trekinc.com/ TREK, Inc.]76 * [http://www.xantrex.com Xantrex Technology]77 78 === Diverse ===79 * [http://www.mcmaster.com McMaster] (Everything. Really. A brilliant resource.)80 * [http://www.labrecyclers.com/ Lab Recyclers] (sell used/refurbished lab equipment)81 * [http://www.uccomponents.com/ UC Components] (vented screws)82 * [http://www.a-msystems.com/ A-M Systems] (Banana cables, BNC Tees)83 * [http://www.a3bs.com/ American 3B Scientific] (general lab equipment; have inexpensive sets of Banana cables)84 * [http://www.l-com.com/home.aspx L-Com] (everything BNC cable related)85 * [http://store.a2zcable.com/index.html A2ZCables] (also inexpensive for BNC cables)86 * [http://www.action-electronics.com/bncconnectors.htm#Cables Action Electronics] (BNC cables again)87 * [http://www.aaronia.de/ Aaaronia] (Xavier's source for magnetic shielding)88 * [http://www.beamimaging.com] (very nice Quadrupole deflector and beam imaging devices)89 * [http://www.colutron.com/products/] (ion sources and other ion beam relevant stuff)90 * [http://www.allectra.com/pdf/Kaptonwires.pdf] (kapton wire)91 92 == Other interesting links ==93 94 * [http://www.casetechnology.com/source.html Case Technology] (Very nice ion sources overview)95 44 96 45 … … 147 96 Vaktrak was originally made for accelerator applications: big tubes, where do you have to place pumps to get a good flat pressure profile over the whole thing. So what Vaktrak thinks is a good vacuum system is: large conductances, pumps seperated by some distance, all essentially pumping the same chamber. Our application is really the contrary: each pump pumps its own chamber, and we want to separate them as good as possible. For Vaktrak (or any other program using the standard formulae of vacuum technology and transfer matrices to solve them), this doesn't seem right, since it thinks that you want to pump your accelerator (which you don't have) through a small nozzle. In other words: numerics become unstable in the differential pumping section (the small conductance), because Vaktrak thinks the pumps in the dumps are meant to pump the source section, too. Vakloop doesn't have that problem. It considers each segment separately and connects them later, so it is really 148 97 much more applicable to our differential pumping problem. 98 99 [../ Return to Savin Group Start Page]
