Changes between Version 8 and Version 9 of SavinGroup/MergedBeams/FirstLeg


Ignore:
Timestamp:
09/20/07 14:59:48 (19 years ago)
Author:
Hjalmar Bruhns
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • SavinGroup/MergedBeams/FirstLeg

    v8 v9  
    1414
    1515== Miniature Einzel Lens == #Einzel
    16 Our Einzel lens sits right after the exit of the [https://docs.astro.columbia.edu/wiki/SavinGroup/MergedBeams/IonSource#ExB Wien Filter] that cleans up our beam from whatever other ions/electrons are extracted from the plasma in the source. To catch the beam at a small diameter, we need to put the Einzel Lens very close to the Wien Filter exit aperture. Following advice from Michael Rappaport, we have used ceramic balls as spacers between the three elements. A 45 mil (1.15mm) diameter wire is [http://en.wikipedia.org/wiki/Tig_welding TIG welded] to the top of the central lens element. Next time we should use a smaller diameter wire: the welder likes thicker wires because they don't just evaporate when he does the weld, we like a thicker diameter because it gives the wire stability, but we will still have to bend it. In the DIN100 Tee we used we had only little access to bend the wire at the right position, and it was a bit of a fight to make the connection to the electrical feedthrough nice and sound. The lens has now been conditioned to 25kV, which should be more than enough for everything we plan to do with it. Note that the only flange that can be opened without damaging anything is the downstream-flange of the tee (because of the electrical connection)! Here are some pics:
     16Our Einzel lens sits right after the exit of the [https://docs.astro.columbia.edu/wiki/SavinGroup/MergedBeams/IonSource#ExB Wien Filter] that cleans up our beam from whatever other ions/electrons are extracted from the plasma in the source. To catch the beam at a small diameter, we need to put the Einzel Lens very close to the Wien Filter exit aperture. Following advice from Michael Rappaport, we have used ceramic balls as spacers between the three elements. A 45 mil (1.15mm) diameter wire is [http://en.wikipedia.org/wiki/Tig_welding TIG welded] to the top of the central lens element. Next time we should use a smaller diameter wire: the welder likes thicker wires because they don't just evaporate when he does the weld, we like a thicker diameter because it gives the wire stability, but we will still have to bend it. In the DIN100 Tee we used we had only little access to bend the wire at the right position, and it was a bit of a fight to make the connection to the electrical feedthrough nice and sound. The lens has now been conditioned to 25kV, which should be more than enough for everything we plan to do with it. Note that the only flange that can be opened without damaging anything is the downstream-flange of the tee (because of the electrical connection)! For our reference, here's the [https://docs.astro.columbia.edu/wiki/SavinGroup/MergedBeams/PartsLists#2ndEinzel parts list], and for the casual reader here are some pics:
    1717
    1818